Vestnik KRAUNC. Fiziko-Matematicheskie Nauki
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Guidelines for authors
Submit a manuscript

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Vestnik KRAUNC. Fiz.-Mat. Nauki:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Vestnik KRAUNC. Fiziko-Matematicheskie Nauki, 2021, Volume 34, Number 1, Pages 203–211
DOI: https://doi.org/10.26117/2079-6641-2021-34-1-203-211
(Mi vkam467)
 

INSTRUMENTS AND METHODS OF MEASUREMENT

Influence of ambient temperature on gamma scintillation detector readings

E. Yeboaha, S. V. Smirnovb, G. A. Yakovlevc

a Tomsk Polytechnic University
b Institute of Monitoring of Climatic and Ecological Systems of the Siberian Branch of Russian Academy of Sciences
c Tomsk State University
References:
Abstract: Scintillation detectors, which are widely used in environmental field study for measurement of radiation dose, are devices that experience wide range of temperature changes when in use. One of the characteristic of scintillation detectors are that, they are very sensitive to change in temperature and hence, every scintillation detector have temperature stabilization inside them. The temperature-dependence coefficient which is part of the detector calculation is the simplest stabilization method that is used. In this work, the BDKG-03 scintillation detector which is used to measure gamma radiation was operated under a controlled condition using a climatic chamber. The BDKG-03 scintillation detector has a temperature stabilizing built-in algorithm. The dose rate and count rate of the gamma background radiation for different temperatures ranging from -40 – +40 ^{\circ}C in increment of 10 ^{\circ}C were measured and studied. The main aim of this work was to study the effect of different ranges of temperature for subsequent calculation of temperature correction coefficient. An analytical result from the experimental result shows that dose rate measurement using the built-in algorithm gives a precise reading as temperature increases. The temperature correction coefficient was found based on dependence.
Keywords: dose rate, scintillation detector, climatic chamber, temperature correction coefficient, radiation.
Document Type: Article
UDC: 550.35
MSC: 86A10
Language: English
Citation: E. Yeboah, S. V. Smirnov, G. A. Yakovlev, “Influence of ambient temperature on gamma scintillation detector readings”, Vestnik KRAUNC. Fiz.-Mat. Nauki, 34:1 (2021), 203–211
Citation in format AMSBIB
\Bibitem{YebSmiYak21}
\by E.~Yeboah, S.~V.~Smirnov, G.~A.~Yakovlev
\paper Influence of ambient temperature on gamma scintillation detector readings
\jour Vestnik KRAUNC. Fiz.-Mat. Nauki
\yr 2021
\vol 34
\issue 1
\pages 203--211
\mathnet{http://mi.mathnet.ru/vkam467}
\crossref{https://doi.org/10.26117/2079-6641-2021-34-1-203-211}
Linking options:
  • https://www.mathnet.ru/eng/vkam467
  • https://www.mathnet.ru/eng/vkam/v34/i1/p203
  • Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Vestnik KRAUNC. Fiziko-Matematicheskie Nauki Vestnik KRAUNC. Fiziko-Matematicheskie Nauki
    Statistics & downloads:
    Abstract page:85
    Full-text PDF :30
    References:13
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2024