LETTERS TO THE EDITORS
On the phase shift in a uniformly rotating Michelson interferometer (comment on “Quadratic Sagnac effect — the influence of the gravitational potential of the Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921–1926)” by G B Malykin and V I Pozdnyakova [Phys. Usp. 58 398 (2015); Usp. Fiz. Nauk 185 431 (2015)])
P. Maraner School of Economics and Management, Free University of Bozen-Bolzano
Abstract:
It is argued that the ‘quadratic Sagnac effect’ recently put forward by G B Malykin and V I Pozdnyakova is the consequence of an incorrect estimation of second-order relativistic corrections and not a real physical phenomenon. The correct expression for the phase shift induced by rotations in a Michelson interferometer is presented.
Received: August 28, 2015 Accepted: December 15, 2015
Citation:
P. Maraner, “On the phase shift in a uniformly rotating Michelson interferometer (comment on “Quadratic Sagnac effect — the influence of the gravitational potential of the Coriolis force on the phase difference between the arms of a rotating Michelson interferometer (an explanation of D C Miller's experimental results, 1921–1926)” by G B Malykin and V I Pozdnyakova [Phys. Usp. 58 398 (2015); Usp. Fiz. Nauk 185 431 (2015)])”, UFN, 186:7 (2016), 793–795; Phys. Usp., 59:7 (2017), 716–718
Linking options:
https://www.mathnet.ru/eng/ufn5401 https://www.mathnet.ru/eng/ufn/v186/i7/p793
|
|