This article is cited in 14 scientific papers (total in 14 papers)
Short Communications
Influence of the structure of a droplet sheet on the capacity of frameless space radiators and the efficiency of the power units
A. A. Koroteeva, A. A. Safronovb, N. I. Filatovb a Moscow Aviation Institute (National Research University)
b Federal State Unitary Enterprise "Keldysh Research Center", Moscow
Abstract:
The development of a fine-dispersed droplet sheet of optimal structure for frameless space lowtemperature heat rejection systems is considered. The possibility of an optimal combination of the thermal capacity rejected by a droplet radiative cooler and the predicted efficiency of the space power unit is substantiated. The dependences of the basic thermal characteristics on the number of droplet planes used have been derived for low- and medium-temperature radiators with an ionic-liquid-based heat carrier.
Received: 04.02.2016
Citation:
A. A. Koroteev, A. A. Safronov, N. I. Filatov, “Influence of the structure of a droplet sheet on the capacity of frameless space radiators and the efficiency of the power units”, TVT, 54:5 (2016), 817–820; High Temperature, 54:5 (2016), 767–770