This article is cited in 1 scientific paper (total in 1 paper)
Resonator elements and control parameters laser
Pulse shortening in a mode-locked YAG:Nd laser using the colliding pulse method
G. P. Banfi, G. Gabetta, P. G. Gobbi, G. C. Reali
Abstract:
Mode locking in a pulsed YAG:Nd laser was studied using the colliding pulse method in a passive antiresonant ring interferometer. The results were compared with those obtained when a cell filled with a dye located next to a nontransmitting resonator mirror was used for mode locking. It was found that the colliding pulse method nearly halved the pulses, was characterized by good amplitude stability and short-term reliability, but suffered from poor long-term stability. Possible causes of the instability and also the mechanism of this pulse shortening are discussed.
Received: 26.10.1989
Citation:
G. P. Banfi, G. Gabetta, P. G. Gobbi, G. C. Reali, “Pulse shortening in a mode-locked YAG:Nd laser using the colliding pulse method”, Kvantovaya Elektronika, 17:10 (1990), 1294–1298 [Sov J Quantum Electron, 20:10 (1990), 1203–1206]
Linking options:
https://www.mathnet.ru/eng/qe7443 https://www.mathnet.ru/eng/qe/v17/i10/p1294
|
Statistics & downloads: |
Abstract page: | 135 | Full-text PDF : | 66 | First page: | 1 |
|