Laser applications and other topics in quantum electronics
Frequency dispersion of a Fabry — Perot interferometer with a small distance between the mirrors
Yu. V. Troitskii Institute of Automation and Electrometry, Siberian Branch of Russian Academy of Sciences, Novosibirsk
Abstract:
A study is reported of the influence of the frequency instability of a light source on a Fabry — Perot interferometer designed for measuring small displacements. A reduction in the interferometer base l reduces the dispersion, but only up to a certain limit corresponding to l ≈ (0.5 — 1)λ. For dielectric mirrors this limit is related to the intrinsic dispersion of the mirrors, which is independent of l and which corresponds approximately to lmirr ≈ 0.3λ. Silver mirrors are characterised by lmirr ≈ 0, but the useful working range begins from l ≥ 0.4λ. The cases of a metal mirror used in combination with a ‘detuned’ dielectric mirror and of resonant mirrors in a dispersion-free Fabry — Perot interferometer are discussed.
Received: 01.01.1996
Citation:
Yu. V. Troitskii, “Frequency dispersion of a Fabry — Perot interferometer with a small distance between the mirrors”, Kvantovaya Elektronika, 23:5 (1996), 476–478 [Quantum Electron., 26:5 (1996), 464–466]
Linking options:
https://www.mathnet.ru/eng/qe699 https://www.mathnet.ru/eng/qe/v23/i5/p476
|
Statistics & downloads: |
Abstract page: | 134 | Full-text PDF : | 151 |
|