Kvantovaya Elektronika
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Impact factor
Submit a manuscript

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Kvantovaya Elektronika:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Kvantovaya Elektronika, 2020, Volume 50, Number 9, Pages 882–887 (Mi qe17308)  

This article is cited in 8 scientific papers (total in 8 papers)

Fibre-optic sensors

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

T. O. Lukashovaa, O. E. Naniiab, S. P. Nikitinc, V. N. Treshchikovad

a T8 Scientific and Technical Center LLC, Moscow
b Faculty of Physics, Lomonosov Moscow State University
c T8 Sensor LLC, Moscow
d Kotelnikov Institute of Radioengineering and Electronics, Fryazino Branch, Russian Academy of Sciences
Full-text PDF (923 kB) Citations (8)
References:
Abstract: We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2% and the spatial resolution is about 30 m.
Keywords: optical time-domain reflectometer, Rayleigh temperature sensor, phase-sensitive reflectometer, spatial resolution, measurement accuracy.
Received: 12.12.2019
Revised: 14.02.2020
English version:
Quantum Electronics, 2020, Volume 50, Issue 9, Pages 882–887
DOI: https://doi.org/10.1070/QEL17225
Bibliographic databases:
Document Type: Article
Language: Russian


Citation: T. O. Lukashova, O. E. Nanii, S. P. Nikitin, V. N. Treshchikov, “Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer”, Kvantovaya Elektronika, 50:9 (2020), 882–887 [Quantum Electron., 50:9 (2020), 882–887]
Linking options:
  • https://www.mathnet.ru/eng/qe17308
  • https://www.mathnet.ru/eng/qe/v50/i9/p882
  • This publication is cited in the following 8 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Квантовая электроника Quantum Electronics
    Statistics & downloads:
    Abstract page:214
    Full-text PDF :75
    References:28
    First page:16
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2024