Kvantovaya Elektronika
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Impact factor
Submit a manuscript

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Kvantovaya Elektronika:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Kvantovaya Elektronika, 2015, Volume 45, Number 4, Pages 377–384 (Mi qe16152)  

This article is cited in 5 scientific papers (total in 5 papers)

Laser applications and other topics in quantum electronics

Measurement of transient gas flow parameters by diode laser absorption spectroscopy

M. A. Bol'shova, Yu. A. Kuritsyna, V. V. Ligera, V. R. Mironenkoa, A. I. Nadezhdinskiib, Ya. Ya. Ponurovskiib, S. B. Leonovc, D. A. Yarantsevc

a Institute of Spectroscopy, Russian Academy of Sciences, Troitsk, Moscow
b A. M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow
c Institute of Extremal States Thermophysics, Scientific Association for High Temperatures, Russian Academy of Sciences, Moscow
Full-text PDF (896 kB) Citations (5)
References:
Abstract: An absorption spectrometer based on diode lasers is developed for measuring two-dimension maps of temperature and water vapour concentration distributions in the combustion zones of two mixing supersonic flows of fuel and oxidiser in the single run regime. The method of measuring parameters of hot combustion zones is based on detection of transient spectra of water vapour absorption. The design of the spectrometer considerably reduces the influence of water vapour absorption along the path of a sensing laser beam outside the burning chamber. The optical scheme is developed, capable of matching measurement results in different runs of mixture burning. A new algorithm is suggested for obtaining information about the mixture temperature by constructing the correlation functions of the experimental spectrum with those simulated from databases. A two-dimensional map of temperature distribution in a test chamber is obtained for the first time under the conditions of plasma-induced combusion of the ethylene – air mixture.
Keywords: absorption spectroscopy, diode laser, gas flow probing, measurements of temperature and concentration.
Received: 19.06.2014
Revised: 22.07.2014
English version:
Quantum Electronics, 2015, Volume 45, Issue 4, Pages 377–384
DOI: https://doi.org/10.1070/QE2015v045n04ABEH015590
Bibliographic databases:
Document Type: Article
PACS: 42.55.Px, 42.62.Fi, 07.07.Df
Language: Russian


Citation: M. A. Bol'shov, Yu. A. Kuritsyn, V. V. Liger, V. R. Mironenko, A. I. Nadezhdinskii, Ya. Ya. Ponurovskii, S. B. Leonov, D. A. Yarantsev, “Measurement of transient gas flow parameters by diode laser absorption spectroscopy”, Kvantovaya Elektronika, 45:4 (2015), 377–384 [Quantum Electron., 45:4 (2015), 377–384]
Linking options:
  • https://www.mathnet.ru/eng/qe16152
  • https://www.mathnet.ru/eng/qe/v45/i4/p377
  • This publication is cited in the following 5 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Квантовая электроника Quantum Electronics
    Statistics & downloads:
    Abstract page:313
    Full-text PDF :105
    References:42
    First page:9
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2024