Lasers
Raman laser with intracavity conversion of 1.34-μm laser radiation in a BaWO4 crystal
A. V. Gavrilov, M. N. Ershkov, A. V. Fedin V. A. Degtyarev Kovrov State Technological Academy, Kovrov, Vladimir region
Abstract:
Intracavity Raman conversion of 1.34-μm radiation of a Nd : YAG laser by a BaWO4 crystal into the 1.53-μm first-Stokes component is studied in different operation regimes. In the case of passive Q-switching of the Nd : YAG laser, the SRS radiation has an average power of 0.28 W with a pulse train energy up to 5 mJ, an individual pulse duration of 19 ns, and a pump pulse repetition rate of 15 Hz. In the case of active Q-switching, the average SRS power is 0.85 W at a pulse energy up to 28 mJ, a pulse duration of 20 ns, and a pump pulse repetition rate of 30 Hz.
Keywords:
stimulated Raman scattering, BaWO4 crystal, Nd:YAG laser, Q-switching.
Received: 13.05.2013 Revised: 26.07.2013
Citation:
A. V. Gavrilov, M. N. Ershkov, A. V. Fedin, “Raman laser with intracavity conversion of 1.34-μm laser radiation in a BaWO4 crystal”, Kvantovaya Elektronika, 43:12 (2013), 1107–1109 [Quantum Electron., 43:12 (2013), 1107–1109]
Linking options:
https://www.mathnet.ru/eng/qe15225 https://www.mathnet.ru/eng/qe/v43/i12/p1107
|
Statistics & downloads: |