Kvantovaya Elektronika
RUS  ENG    JOURNALS   PEOPLE   ORGANISATIONS   CONFERENCES   SEMINARS   VIDEO LIBRARY   PACKAGE AMSBIB  
General information
Latest issue
Archive
Impact factor
Submit a manuscript

Search papers
Search references

RSS
Latest issue
Current issues
Archive issues
What is RSS



Kvantovaya Elektronika:
Year:
Volume:
Issue:
Page:
Find






Personal entry:
Login:
Password:
Save password
Enter
Forgotten password?
Register


Kvantovaya Elektronika, 2013, Volume 43, Number 12, Pages 1165–1169 (Mi qe15222)  

This article is cited in 1 scientific paper (total in 1 paper)

Optical coherence tomography

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

A. N. Morozovab, I. V. Turchinab

a Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod
b Nizhny Novgorod State Medical Academy
References:
Abstract: The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained.
Keywords: parallel OCT, optical fibre, diffraction grating, linear 2π modulation.
Received: 25.04.2013
Revised: 18.06.2013
English version:
Quantum Electronics, 2013, Volume 43, Issue 12, Pages 1165–1169
DOI: https://doi.org/10.1070/QE2013v043n12ABEH015222
Bibliographic databases:
Document Type: Article
PACS: 42.30.Wb, 87.63.L-, 07.60.Ly, 07.60.Vg
Language: Russian


Citation: A. N. Morozov, I. V. Turchin, “Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators”, Kvantovaya Elektronika, 43:12 (2013), 1165–1169 [Quantum Electron., 43:12 (2013), 1165–1169]
Linking options:
  • https://www.mathnet.ru/eng/qe15222
  • https://www.mathnet.ru/eng/qe/v43/i12/p1165
  • This publication is cited in the following 1 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Квантовая электроника Quantum Electronics
    Statistics & downloads:
    Abstract page:181
    Full-text PDF :93
    References:43
    First page:3
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2024