This article is cited in 1 scientific paper (total in 1 paper)
Human eye optics
Determination of positions of optical elements of the human eye
S. O. Galetskii, T. Yu. Cherezova Lomonosov Moscow State University, Faculty of Physics
Abstract:
An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.
Received: 02.10.2008 Revised: 24.11.2008
Citation:
S. O. Galetskii, T. Yu. Cherezova, “Determination of positions of optical elements of the human eye”, Kvantovaya Elektronika, 39:2 (2009), 201–203 [Quantum Electron., 39:2 (2009), 201–203]