Fiber and integrated optics. fiber waveguide devices
Fiber Michelson interferometer with a 50-km difference between its arms
E. M. Dianov, A. V. Kuznetsov, A. Yu. Makarenko, O. G. Okhotnikov, A. M. Prokhorov, E. A. Shcherbakov
Abstract:
Single-mode fiber waveguides were used in constructing a Michelson interferometer with a 50-km difference between its arm lengths. An analysis was made of its resolving power as a function of the parameters of the optical part and of the characteristics of the electronic apparatus used in the system. The width of a spectral emission line of a semiconductor laser with a distributed Rayleigh fiber resonator was determined.
Received: 13.07.1989
Citation:
E. M. Dianov, A. V. Kuznetsov, A. Yu. Makarenko, O. G. Okhotnikov, A. M. Prokhorov, E. A. Shcherbakov, “Fiber Michelson interferometer with a 50-km difference between its arms”, Kvantovaya Elektronika, 17:12 (1990), 1593–1596 [Sov J Quantum Electron, 20:12 (1990), 1490–1492]
Linking options:
https://www.mathnet.ru/eng/qe12553 https://www.mathnet.ru/eng/qe/v17/i12/p1593
|
|