This article is cited in 1 scientific paper (total in 1 paper)
Lasers and amplifiers
Operational stability of a compact 600-W KrF laser
V. M. Borisova, A. Yu. Vinokhodova, V. A. Vodchitsa, A. V. El'tsova, D. Bastingb, U. Stammb, F. Vossb a Troitsk Institute for Innovation and Fusion Research
b Lambda Physik GmbH, Gottingen, Germany
Abstract:
The problem of the operational stability of a KrF laser with an average output power of at least 600 W was investigated. An experimental study was made of the dependences of the rms deviation σ of the output energy on the charging voltage, on the pulse repetition rate, and on the operating time. The value of σ varied from 1.2% to 6.0%, depending on the experimental conditions. For an average power of ~600 W, the deviation σ did not exceed 3.2%.
Received: 17.09.1997
Citation:
V. M. Borisov, A. Yu. Vinokhodov, V. A. Vodchits, A. V. El'tsov, D. Basting, U. Stamm, F. Voss, “Operational stability of a compact 600-W KrF laser”, Kvantovaya Elektronika, 25:2 (1998), 131–134 [Quantum Electron., 28:2 (1998), 123–126]
Linking options:
https://www.mathnet.ru/eng/qe1185 https://www.mathnet.ru/eng/qe/v25/i2/p131
|
Statistics & downloads: |
Abstract page: | 150 | Full-text PDF : | 71 | First page: | 1 |
|