This article is cited in 1 scientific paper (total in 1 paper)
Laser applications and other topics in quantum electronics
Determination of the sensitivity of an autodyne acoustooptic fiber-waveguide transducer
Yu. A. Kravtsov, N. I. Kolesnikov, B. I. Levit, A. I. Minchenko, B. N. Tumanov
Abstract:
A study was made of the parameters governing the maximum sensitivity of an autodyne acoustooptic fiber-waveguide transducer. When the fiber length was 10 m, the wavelength was 0.63 μm and the threshold sensitivity of the transducer was 1.5 X 10–5 Pa · Hz–1/2 at the quantum limit. This autodyne sensor was used in calibration of a source of acoustic-frequency pressures. The threshold sensitivity was determined experimentally for a laser autodyne transducer utilizing a single-mode quartz waveguide with a lacquer coating: when the waveguide length was 2 m the sensitivity amounted to 5 X 10–4 Pa · Hz–1/2 if an LG-77 laser was used.
Received: 27.05.1987
Citation:
Yu. A. Kravtsov, N. I. Kolesnikov, B. I. Levit, A. I. Minchenko, B. N. Tumanov, “Determination of the sensitivity of an autodyne acoustooptic fiber-waveguide transducer”, Kvantovaya Elektronika, 15:3 (1988), 601–605 [Sov J Quantum Electron, 18:3 (1988), 382–385]