Abstract:
The limit load is one of the main characteristics in estimating the performance of different structures, in particular, structures with soft welded (soldered) joints. In some cases, the difference between the yield strengths of the main material and the joint material is so great that plastic strain is localized in a thin joint. With some features of such strain distribution taken into account, an upper bound of the limit load of a tensile axisymmetric sample with a crack in a welded (soldered) joint is obtained.
Keywords:
welded or soldered structures, crack, limit load, upper bound.