This article is cited in 4 scientific papers (total in 4 papers)
IR-radiation detection by ultrasonic thermometry
D. V. Petrovab, D. E. Geninc, V. A. Korolkova a Institute of Monitoring of Climatic and Ecological Systems, Siberian Branch of the Russian Academy of Science, Tomsk
b Tomsk State University
c Institute of High Current Electronics, Siberian Branch of the Russian Academy of Sciences, Tomsk
Abstract:
A method based on ultrasonic thermometry for detecting radiation in the IR range is described. The first results of experimental verification of this method are presented using the example of CO$_2$-laser-radiation detection, and ways to improve its threshold sensitivity are described.
Received: 17.05.2016
Citation:
D. V. Petrov, D. E. Genin, V. A. Korolkov, “IR-radiation detection by ultrasonic thermometry”, Pisma v Zhurnal Tekhnicheskoi Fiziki, 43:9 (2017), 20–26; Tech. Phys. Lett., 43:5 (2017), 421–423
Linking options:
https://www.mathnet.ru/eng/pjtf5924 https://www.mathnet.ru/eng/pjtf/v43/i9/p20
|
Statistics & downloads: |
Abstract page: | 45 | Full-text PDF : | 22 |
|