Zhurnal Tekhnicheskoi Fiziki, 2016, Volume 86, Issue 6, Pages 121–125
(Mi jtf6534)
|
|
|
|
This article is cited in 2 scientific papers (total in 2 papers)
Electrophysics, electron and ion beams, physics of accelerators
Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses
E. I. Pal'chikovab, A. M. Ryabchunab a Lavrentyev Institute of Hydrodynamics of Siberian Branch of the Russian Academy of Sciences, Novosibirsk
b Novosibirsk State University
Abstract:
The speed and efficiency of the Tesla transformer at the first half-wave of the output voltage are studied as a function of the Q factors of the circuits and their coupling factor. Calculated results and experimental data are considered. It is shown that for given Q factors, there is an optimal value of the coupling factor providing the highest efficiency, which can be calculated and for which designers should work.
Received: 17.06.2015
Citation:
E. I. Pal'chikov, A. M. Ryabchun, “Analysis of the Tesla transformer operation at the first half-wave of the output voltage taking into account ohmic losses”, Zhurnal Tekhnicheskoi Fiziki, 86:6 (2016), 121–125; Tech. Phys., 61:6 (2016), 919–923
Linking options:
https://www.mathnet.ru/eng/jtf6534 https://www.mathnet.ru/eng/jtf/v86/i6/p121
|
Statistics & downloads: |
Abstract page: | 44 | Full-text PDF : | 14 |
|