Abstract:
A study has been carried out of the electron-optical properties of improved design of the cylindrical mirror energy analyzer. Both external and internal electrodes of the analyzer are divided into three isolated parts, whereby the potentials on the individual parts can be regulated independently from each other. In symmetric operating mode at identical potentials on the side parts of the electrodes, a significant increase has been obtained in resolving power and light-gathering power of the analyzer compared to the standard design of the cylindrical mirror. In asymmetric operating mode, which is implemented in a linear potential distribution on the external electrode, the conditions have been found under which the linear dispersion of the analyzer increases several times.
Received: 29.06.2016
Citation:
L. A. Baranova, “Improved cylindrical mirror energy analyzer”, Zhurnal Tekhnicheskoi Fiziki, 87:3 (2017), 458–461; Tech. Phys., 62:3 (2017), 480–483