This article is cited in 1 scientific paper (total in 1 paper)
Electrophysics
Increased efficiency of systems for remote radiation monitoring based on linear electron accelerator
B. Yu. Bogdanovich, G. O. Buyanov, A. V. Nesterovich National Engineering Physics Institute "MEPhI", Moscow
Abstract:
System for preliminary cooling of electron beam and decrease in the angular divergence of flux of quanta due to multiple passages of the electron beam in a chamber placed in a transverse magnetic field is considered. Cooling of the electron beam is provided by specific configuration of the magnetic field. In the proposed system, the phase portrait undergoes the simplest changes: a stepwise increase in the foil with stretching along the vertical direction, rotation around the origin of coordinates, and horizontal positioning after focusing. Thus, the transverse dimensions of the beam increase and the angular spread at least does not increase (as without cooling).
Keywords:
introscopy, tomography, bremsstrahlung, output device, electron beam.
Received: 26.10.2020 Revised: 09.02.2021 Accepted: 11.02.2021
Citation:
B. Yu. Bogdanovich, G. O. Buyanov, A. V. Nesterovich, “Increased efficiency of systems for remote radiation monitoring based on linear electron accelerator”, Zhurnal Tekhnicheskoi Fiziki, 91:7 (2021), 1174–1181; Tech. Phys., 66:8 (2021), 969–976
Linking options:
https://www.mathnet.ru/eng/jtf4979 https://www.mathnet.ru/eng/jtf/v91/i7/p1174
|