Fizika Goreniya i Vzryva, 2020, Volume 56, Issue 6, Pages 85–94
DOI: https://doi.org/10.15372/FGV20200609
(Mi fgv724)
 

This article is cited in 1 scientific paper (total in 1 paper)

Direct lightning initiation of HMX

K. C. Chen, L. K. Warne, R. E. Jorgenson, J. H. Niederhaus

Sandia National Laboratories, 87185, Albuquerque, USA
Citations (1)
Abstract: HMX can be detonated by an exploding bridgewire (EBW) or a slapper. Direct HMX detonation by an electrical arc has not been demonstrated. This paper shows that the shock from a 99% worst-case lightning current (200 kA and 500 ns rise time) can detonate standard-density HMX at elevated temperatures (i.e., HMX in the most sensitive $\delta$-phase at a temperature above 177$^\circ$C) and that the shock from a 200-kA peak current pulse with a 100 ns rise time can detonate HMX at ambient temperatures. Two necessary detonation conditions are used for these assertions. The relevant Pop-Plot for HMX is converted into an empirical detonation criterion, which is applicable to explosives subject to shocks of variable pressure. The minimum detonation spot size for detonation reported in the literature is used as the other condition. PBX-9501 and LX-04 have similar Pop-Plots to those of HMX; thus, the HMX result is directly applicable. Although PBX-9404 and PBX-9407 are HMX-based, they have somewhat lower Pop-Plot pressures than HMX and are more sensitive to shocks caused by electrical arcs than HMX. As the HMX thermal conductivity is low and the phase transition can be slow, the chance of having a sufficient amount of HMX converted to $\delta$-HMX during an accident is small; therefore, the threat of lightning shock-detonating HMX is very low. We recommend lightning simulation tests to be conducted for $\delta$-HMX. We also would like to point out that a lightning can ignite HMX, which, in turn, leads to detonation via the deflagration-to-detonation transition.
Keywords: HMX, detonation, deflagration, lightning, shock.
Funding agency Grant number
Honeywell International Inc. DE-NA0003525
Received: 17.09.2019
Revised: 10.01.2020
Accepted: 19.02.2020
English version:
Combustion, Explosion and Shock Waves, 2020, Volume 56, Issue 6, Pages 697–704
DOI: https://doi.org/10.1134/S001050822006009X
Bibliographic databases:
Document Type: Article
UDC: 535.341, 544.454
Language: Russian
Citation: K. C. Chen, L. K. Warne, R. E. Jorgenson, J. H. Niederhaus, “Direct lightning initiation of HMX”, Fizika Goreniya i Vzryva, 56:6 (2020), 85–94; Combustion, Explosion and Shock Waves, 56:6 (2020), 697–704
Citation in format AMSBIB
\Bibitem{CheWarJor20}
\by K.~C.~Chen, L.~K.~Warne, R.~E.~Jorgenson, J.~H.~Niederhaus
\paper Direct lightning initiation of HMX
\jour Fizika Goreniya i Vzryva
\yr 2020
\vol 56
\issue 6
\pages 85--94
\mathnet{http://mi.mathnet.ru/fgv724}
\crossref{https://doi.org/10.15372/FGV20200609}
\elib{https://elibrary.ru/item.asp?id=44480682}
\transl
\jour Combustion, Explosion and Shock Waves
\yr 2020
\vol 56
\issue 6
\pages 697--704
\crossref{https://doi.org/10.1134/S001050822006009X}
Linking options:
  • https://www.mathnet.ru/eng/fgv724
  • https://www.mathnet.ru/eng/fgv/v56/i6/p85
  • This publication is cited in the following 1 articles:
    Citing articles in Google Scholar: Russian citations, English citations
    Related articles in Google Scholar: Russian articles, English articles
    Fizika Goreniya i Vzryva Fizika Goreniya i Vzryva
    Statistics & downloads:
    Abstract page:33
     
      Contact us:
     Terms of Use  Registration to the website  Logotypes © Steklov Mathematical Institute RAS, 2024