Abstract:
An experimental method is proposed for the estimation of the temperature at the leading edge of the conducting zone in combustion waves in nonconducting condensed systems. Experiments using the Zr + WO$_3$ system demonstrated the effectiveness of the method. The temperature of the leading edge is found to be 2000–2400 K for a combustion temperature of the system of $\approx$ 3000 K.
Received: 26.02.1999 Accepted: 17.08.1999
Citation:
V. F. Proskudin, “Temperature measurements at the leading edge of the conducting zone of a condensed-system combustion wave”, Fizika Goreniya i Vzryva, 36:2 (2000), 84–87; Combustion, Explosion and Shock Waves, 36:2 (2000), 236–239